Contact Us
The latest company news and electrical products from E Preston Electrical

Browse By Category

Browse By Date

E. Preston Electrical

Company News

Honeywell Infrared Sensors

December 22, 2006

Logo.jpg

Overview:
Optoelectronics is the integration of optical principles and semiconductor electronics. Optoelectronic components are reliable, cost-effective sensors. Standard infrared emitting diodes (IREDs), sensors and assemblies are covered.

Infrared (2).jpg

Best Used For:
Object presence sensing, motion sensing, position encoding, limit sensing, movement detection and counting.

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

Moeller’s Versatile New Breakers Switch 15kA

December 22, 2006

Moeller-Logo jpg.jpg

Just 17.5mm wide for single pole versions and 52.5mm wide for triple-pole types, Moeller Electric’s new Xpole FAZ miniature circuit breakers (MCBs) have a breaking capacity of 15kA, in line with IEC/EN6094. This makes them an attractive and cost-effective choice for use in industrial applications where space is always at a premium, and high prospective fault currents are often encountered.

In addition to the standard B, C and D trip characteristics, Moeller is offering Xpole FAZ MCBs with the new Z, K and S characteristics, which are of particular interest to OEMs and designers of automation systems.

xpole_faz_group.jpg

Specifically designed to protect sensitive electronic equipment, the Z characteristic has a short-circuit response current of 2 to 3 In, combined with quick-reaction overload protection. The K characteristic has a short-circuit response current of 8 to 12 In, which prevents nuisance tripping with three-phase loads such as motors, while the S characteristic with its exceptionally high 13 to 17 In short-circuit response provides a complete solution to the problem of protecting control transformers and other loads with very high inrush currents.

Moeller Electric's new Xpole FAZ MCBs are available with ratings from 0.5A to 63A, and are offered in single-, double-, three- and four-pole versions. All types comply with a broad range of national and international standards, including UL and CSA, there is even a special series of devices which fully comply with UL489.

A range of accessories, which includes auxiliary signalling contacts and shunt-trip mechanisms, provides additional functionality. To ensure fast and easy assembly, most accessories simply snap into place without the need to use tools. The breakers themselves are designed for convenient mounting on standard DIN rail.

The new compact Xpole FAZ MCBs are complemented by an extensive family of RCCBs, combined RCD/MCBs (RCBOs) and control devices. The PKNM combined RCD/MCBs offer triple protection in a single device, namely overload, short-circuit and residual current protection in the space of only two MCB widths. Catering for either B or C characteristics, they are available from 6A to 40A with rated fault currents of 30mA or 300mA.

Xpole type AZ MCBs are also available for use in applications where current ratings up to 125A and a switching capacity greater than 15kA is needed.

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

HONEYWELL GSS Series Hinge Actuated Safety Switch

December 17, 2006

Logo.jpg

GSS Series, Safety Limit Switch, 3NC/1NO Direct Opening, Slow Action, Hinge Mount, 1/2 NPT, EN50047 Compatible, Zinc Die-cast, Gold-plated Contacts

FEATURES

• Positive opening operation of normally closed contacts
• Available with up to 4NC positive opening contacts
• Galvanically isolated contacts
• Available with gold-plated contacts for improved switching reliability at low currents and voltages
• Wide selection of actuators
• UL, CSA, CE, BG pending

GSDA03S2.jpg

TYPICAL APPLICATIONS

• Machine tools
• Material handling equipment
• Packaging machinery
• Textile machinery
• Construction machinery and equipment

DESCRIPTION

The GSS Series Global Safety Switch is available in three configurations:
• GSA - Standard mounting per EN50041
• GSC - Standard mounting per EN50047
• GSE - Compatible with standard mounting per EN50047

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

JCB DIESELMAX to the MAX with the Protection of E-T-A

December 17, 2006

 eta logo.jpg

Many of you will have been aware that the JCB DIESELMAX car became the world’s fastest diesel-powered automobile in August when Wing Commander Andy Green drove it to a new record of 350.092mph (563.418kph) after two passes in opposite directions, within one hour, on Bonneville Salt Flats in Utah. But how many of you knew that the electrical circuits were protected by E-T-A circuit breakers?!

Sir Anthony Bamford, Chairman of privately owned JCB, was very clear why he wanted to build a JCB record-breaker when the project was started: “I am passionate about the importance of engineering excellence to Britain and I see using the JCB engine for this record attempt as a fantastic way of showcasing what British engineers can do. The JCB444 has been acknowledged as a remarkable piece of engineering, and this programme to build the world’s fastest diesel-powered automobile is precisely the sort of technical challenge that we should rise to.”

JCB DIESELMAX 5.jpg

Powering the stunning, nine metre long JCB DIESELMAX car were two JCB444 diesel engines, developed with the help of Ricardo engineers to produce 750bhp each, five times the power needed to drive a JCB backhoe loader, and now the world’s most powerful diesel engine per litre. The JCB444-LSR engine displaces 5-litres, weighs 382 kg (dry), and produces 750bhp at 3,800 rpm on a relatively low 10.5:1 compression ratio and in excess of 1500 Nm of torque at 2,500 rpm.

The distribution panel was designed and built by R&D Vehicle Systems, based in Banbury. Rob Millar,director of RDVS, explained: “R&D Vehicle Systems is a specialist designer and supplier of electrical systems for military and niche vehicle manufacturers. We were delighted to be involved in the JCB DIESELMAX project. The superior technology and reliability of E-T-A’s circuit breakers are well known to us. It was very important for this project that we could build a system using circuit breakers that were very resilient to shock and capable of resisting damaging ingress of salt and oil.  For this reason we chose E-T-A type 483s, which we know are highly ‘spec’ed’ and well proven in motor sport and the aerospace industry, and we fitted them with standard dust covers.

The E-T-A 483 Circuit Breaker for Equipment (CBE) is a single pole temperature compensated thermal circuit breaker. Believed to be the smallest package on the market offering protection up to 35A, the range extends from 1A up to 35A. It features a push/pull on/off actuator with a tease-free, trip-free snap action mechanism. A high tolerance to sudden current surges is in-built, reducing the risk of nuisance operation, and enabling close matching of cable size to CBE. This avoids the common practice of overspecifying the cable size and using a higher rated fuse.

“Although the distribution panel was located behind a closed panel,” Millar continued, “it, nevertheless, was subject to inevitable exposure from fine salt particles and oil spray. We never had a single issue with the circuit breakers. One tripped just the once during the Bonneville runs, and that meant that that section of electrical harness was safely protected against the overcurrent that caused the trip.”

JCB DIESELMAX 2.jpg

Andy Green, the fastest man on Earth, set the first-ever supersonic world land speed record at 763.035 mph in ThrustSSC on the Black Rock Desert on 15 October 1997. As he was feted by his jubilant crew on 23 August, Green said: “I am so pleased that we have got the car to 350mph which was always our ultimate goal and that was with a slow start to the second run. Today’s record proves the potential we have always believed JCB DIESELMAX to possess. This is another great result for a wonderful team and a testament to British engineering.”

"350mph is a fantastic speed for a diesel-powered car. To have built the world's fastest diesel in such a short timescale is a wonderful achievement for the JCB DIESELMAX team,” added Dr Tim Leverton, JCB’s Group Engineering Director and Project Director for the land speed record project. “What is even more impressive is to set three records – 317.021mph, 328.767mph (526.027 kph) and 350.092mph (563.418kph) in only six days.”

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/ 

For more information
We are happy to help!

Featured Products

Manufacturers

Privacy Policy
Website built and optimised by Miltec Digital

Get In Touch

Fill in your details to request a call from one of our sales representatives.
E Preston Contact Form
chevron-leftchevron-right linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram